Discreet Mist Nozzle

Ultimately, once installation of a water mist system is complete, it is the water mist nozzles that are the remaining visible feature. It is therefore important to IPH Mist Suppression that we continued to deliver a premium product to our clientelle. We are therefore delighted to provide the UK’s most discreet water mist nozzle to home owners, developers and architects who are seeking a quality finish without compromising of functionality..

Our water mist nozzles are not only have an easy fix design, but they are extremely low profile sitting just 3mm below the ceiling, with each patented nozzle offering 16 m² of protection. This means that our water mist nozzle design is the sleekest, most aesthetically pleasing on the market currently being installed into thousands of homes across the UK. 

What is a water mist system?

water mist system is a fire protection system which uses very fine water sprays (i.e. water mist). The small water droplets allow the water mist to control, suppress or extinguish fires by: cooling both the flame and surrounding gases by evaporation and displacing oxygen by evaporation.

What is a water mist system?

water mist system is a fire protection system which uses very fine water sprays (i.e. water mist). The small water droplets allow the water mist to control, suppress or extinguish fires by: cooling both the flame and surrounding gases by evaporation and displacing oxygen by evaporation.

Specifications & Features

K Factor: 1.92

Temperature rating: 57°C

Manufacturer: HiPro Industries.

Part Number: PU002-00

Max Pressure: 1020 psi (70 bar)

Response Type: Fast (Residential)

Occupancy Type: Domestic

Connection Size: 3/8” BSP

Min Spacing: 2m (6.5ft)

Max Spacing: 4m x 4m (13.2 x 13.2ft)

Colour: Standard colour white, other colours available on request.

One nozzle protects a 4m x 4m area, it must be a maximum of 2m from a wall and there must be a maximum of 4m between nozzles.

"We are delighted that IPH speed of service and knowledge of Building Reg’s matched with their premium product allowed our Architect creativity in their design and our vision to be realised.”

…another Happy Client

Water Damage is the new Fire Damage.

It is repeatedly documented by Property Insurers that it is the excessive use of water while quenching a fire that is a great financial concern regarding any damage claim.

Our modern and discreet nozzles are designed specifically for the residential and domestic sector by suppressing a fire using a fine mist, allowing minimal damage to occur to both the fabric of the building and material possessions.

Our water mist nozzles are deliberately designed to use 80% less water than traditional sprinkler heads!

No Unnecessary Release

As an additional safety measure to protect against unwanted operation and ultimately needlessley misting up your property, our complete custom built water mist system incorporates a facility to receive an input from the smoke detection system on the pump control and monitoring board. When using this facility, the pumps would need to have both the smoke detection and the nozzle operate before the pumps will run.

If just the nozzle operates, the system will not run. If just the smoke detection operates the system will not run. Both smoke (to operate the detection system) and heat (to operate the nozzle) will need to be present for the system to run

PATENT NOZZLE

Full Spec + Sizing

Our nozzles work by a heat sensitive bulb that when activated, discharges a water mist which removes heat and displaces oxygen from the fire providing fast and effective fire suppression.

NOTICE: The product details indicated are for general reference only and may vary based on the specific product approval and/or application.

Can I change the Nozzle colour? 

Yes, for a premium, the colour of the nozzles can be altered to match any desired colour using the RAL colour code system.

***This may incur longer lead times. 

Increased Fire Safety Measures

 

Following recent Government Legislation change (May 2020), fire suppression systems are now regarded as a mandatory requirement for a wider range of residential and domestic properties and apartment blocks that marks the greatest change to building safety systems in a generation!

The Custom PUMP

The HOSE & Fittings

British Standard

Latest Company News Articles & Case Studies

What are the 2 parts of PAS 79 2020

What are the 2 parts of PAS 79 2020

PAS 79, which was last revised in 2012, provided generic fire risk assessment guidance. However, the housing sector wanted more housing-specific recommendations to be developed. It was therefore decided to revise PAS 79, updating the existing PAS and renaming it as Part 1, and introducing a new, housing-specific, Part 2.

read more
Royal Mist Suppression

Royal Mist Suppression

IPH Mist Suppression have been instructed to protect the artefacts on the mezzanine floor plus the residential area where the Maids live at Blenham Palace.

read more
Ingenious Water Mist System Installers

Ingenious Water Mist System Installers

Fire protection systems have become an integral part of buildings, whether commercial, residential, or industrial, for the safety of the occupants. Since it is the safety of the people and the property we are concerned for, we have to ensure that we choose reliable water mist system installers who know what they are doing and have the appropriate skills and knowledge to install the fire protection system in the building efficiently.

read more